A Minimum 2-Year Follow-up Using Modular Trabecular Metal Tibial Components in Total Knee Arthroplasty

Authors

  • Eddy D Zandee van Rilland University of Maryland School of Medicine
  • Joseph C Varcadipane The Bone and Joint Center at Straub Clinic Honolulu, HI
  • Olga Geling University of Hawaii at Manoa
  • Megan Murai Kuba The Bone and Joint Center at Straub Clinic Honolulu, HI
  • Cass K Nakasone The Bone and Joint Center at Straub Clinic Honolulu, HI

DOI:

https://doi.org/10.15438/rr.5.3.113

Keywords:

total knee arthroplasty, uncemented, cementless, trabecular metal, porous tantalum

Abstract

INTRODUCTION: Early failure of tibial components remains a concern in total knee arthroplasty (TKA). Loss of fixation with cemented implants continues to be problematic in young, active patients.  We sought to determine outcomes in patients receiving trabecular metal (TM) implants in a single-surgeon community hospital setting.

METHODS: A retrospective analysis was performed on 167 consecutive primary TKAs performed on 133 patients utilizing a TM tibial implant with a minimum two years follow-up.

RESULTS: Failure due to aseptic loosening occurred in 4 of the 167 cases (2.4%). Local and systemic complication rates were low. Length of hospital stay and tourniquet time data were also reported.

CONCLUSION: Overall complications were low in our cohort of patients receiving TM implants.  Longer follow-up is necessary to determine if the outcomes we observed are sustained over time.

References

Bourne RB, Finlay JB. The influence of tibial component intramedullary stems and implant-cortex contact on the strain distribution of the proximal tibia following total knee arthroplasty: an in vitro study. Clin Orthop Relat Res. 1986;208:95–99

Dunbar MJ, Wilson DAJ, Hennigar AW, Amirault JD, Gross M, Reardon GP. Fixation of a trabecular metal knee arthroplasty component. A prospective randomized study. J Bone Joint Surg Am. 2009;91:1578–1586

Cawley DT, Kelly N, Simpkin A, Shannon FJ, McGarry JP. Full and surface tibial cementation in total knee arthroplasty: a biomechanical investigation of stress distribution and remodeling in the tibia. Clin Biomech (Bristol, Avon). 2012;27:390-397

Foran JR, Whited BW, Sporer SM. Early aseptic loosening with a precoated low-profile tibial component: a case series. J Arthroplasty. 2011;26:1445-1450

Barrington JW, Sah A, Malchau H, Burke DW. Contemporary cruciate-retaining total knee arthroplasty with a pegged tibial baseplate. Results at a minimum of ten years. J Bone Joint Surg Am. 2009;91:874-878

Miller CW, Pettygrow R. Long-term clinical and radiographic results of a pegged tibial baseplate in primary total knee arthroplasty. J Arthroplasty 2001;16:70

Weeden SH, Ogden SB. Early loosening of MIS tibial implants in primary TKA. American Academy of Orthopaedic Surgeons Annual Meeting. New Orleans, LA; 2010

Anderson DR, Anderson JT. High incidence of aseptic loosening following MIS total knee arthroplasty at short- term follow-up. American Academy of Orthopaedic Surgeons Annual Meeting. Las Vegas, NV; 2009

Lewis G. Properties of acrylic bone cement: state of the art review. J Biomed Mater Res. 1997;38:155-182

Soballe K, Hansen ES, Brockstedt-Rasmussen H, Bunger C. Hydroxyapatite coating converts fibrous tissue to bone around loaded implants. J Bone Joint Surg Br. 1993;75:270-278

Hofmann AA, Evanich JD, Ferguson RP, Camargo MP. Ten- to 14-year clinical followup of the cementless Natural Knee system. Clin Orthop Relat Res. 2001;388:85-94

Baldwin JL, El-Saied MR, Rubinstein RA Jr. Uncemented total knee arthroplasty: report of 109 titanium knees with cancellous-structured porous coating. Orthopedics. 1996;19:123-130

Hofmann AA, Heithoff SM, Camargo M. Cementless total knee arthroplasty in patients 50 years or younger. Clin Orthop Relat Res. 2002;404:102-107

Patil N, Lee K, Goodman SB. Porous tantalum in hip and knee reconstructive surgery. J Biomed Mater Res B Appl Biomater. 2009;89:242-251

Bobyn JD, Stackpool GJ, Hacking SA, Tanzer M, Krygier JJ. Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial. J Bone Joint Surg Br. 1999;81:907-914

Karageorgiou V, Kaplan D. Porosity of 3D biomaterial scaffolds and osteogenesis. Biomaterials. 2005;26:5474–5491

Bobyn JD, Poggie RA, Krygier JJ, Lewallen DG, Hanssen AD, Lewis RJ, Unger AS, et al. Clinical validation of a structural porous tantalum biomaterial for adult reconstruction. J Bone Joint Surg Am. 2004;86A:123-129

Helm AT, Kerin C, Ghalayini SR, McLauchlan GJ. Preliminary results of an uncemented trabecular metal tibial component in total knee arthroplasty. J Arthroplasty. 2009;24:941–944

Ghalayini SR, Helm AT, McLauchlan GJ. Minimum 6year results of an uncemented trabecular metal tibial component in total knee arthroplasty. The Knee. 2012;19:872-874

Unger AS, Duggan JP. Midterm results of a porous tantalum monoblock tibia component. J Arthroplasty. 2011;26:855–860

Kamath AF, Lee GC, Sheth NP, Nelson CL, Garino JP, Israelite CL. Prospective results of uncemented tantalum monoblock tibia in total knee arthroplasty: minimum 5-year follow-up in patients younger than 55 years. J Arthroplasty. 2011;26:1390-1395

Fehring TK, Odum S, Griffin WL, Mason JB, Nadaud M. Early failures in total knee arthroplasty. Clin Orthop Relat Res. 2001;392:315-318

Bozic KJ, Kurtz SM, Lau E, Ong K, Chiu V, Vail TP, Rubash HE, Berry DJ. The epidemiology of revision total knee arthroplasty in the United States. Clin Orthop Relat Res. 2010;468:45-51

Sharkey PF, Hozack WJ, Rothman RH, Shastri S, Jacoby SM. Insall Award paper. Why are total knee arthroplasties failing today? Clin Orthop Relat Res. 2002;404:7-13

Vessely MB, Whaley AL, Harmsen WS, Schleck CD, Berry DJ. The Chitranjan Ranawat Award: Long-term survivorship and failure modes of 1000 cemented condylar total knee arthroplasties. Clin Orthop Relat Res. 2006;452:28-34

Peters CL, Hennessey R, Barden RM, Galante JO, Rosenberg AG. Revision total knee arthroplasty with a cemented posterior-stabilized or constrained condylar prosthesis: a minimum 3-year and average 5-year follow-up study. J Arthroplasty. 1997;12:896-903

Garcia RM, Hardy BT, Kraay MJ, Goldberg VM. Revision total knee arthroplasty for aseptic and septic causes in patients with rheumatoid arthritis. Clin Orthop Relat Res. 2010;468:82-89

Wilson DA, Richardson G, Hennigar AW, Dunbar MJ. Continued stabilization of trabecular metal tibial monoblock total knee arthroplasty components at 5 years measured with radiostereometric analysis. Acta Orthop. 2012;83:36–40

Hayakawa K, Date H, Tsujimura S, Nojiri S, Yamada H, Nakagawa K. Mid-term results of total knee arthroplasty with a porour tantalum monoblock tibial component. Knee. 2014;21(1):199-203

Fernandez-Fiaren M, Hernandez-Vaquero D, Murcia A, Torres A, Llopis R. Trabecular metal in total knee arhtroplasty associated with higher knee scores: a randomized controlled trial. Clin Orthop Relat Res. 2013;471:3543-3553

Pulido L, Abdel MP, Lewallen DG, Stuart MJ, Sanchez-Sotelo J, Hanssen AD, Pagnano MW. Trabecular Metal Tibial Components Were Durable and Reliable in Primary Total Knee Arthroplasty: A Randomized Clinical Trial. Clin Orthop Relat Res. 2014 Apr 1.

Piedade SR, Pinaroli A, Servien E, Neyret P. Revision after early aseptic failures in primary total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2009;17:248-253

Cheng, T., Zhang, G., & Zhang, X. (2011). Imageless Navigation System Does Not Improve Component Rotational Alignment in Total Knee Arthroplasty. Journal of Surgical Research, 171(2), 590–600.

Tigani D, Sabbioni G, Raimondi A. Early aseptic loosening of a porous tantalum knee prosthesis. Chir Organi Mov. 2009;93:187-191

Harrysson OL, Robertsson O, Nayfeh JF. Higher cumulative revision rate of knee arthroplasties in younger patients with osteoarthritis. Clin Orthop Relat Res. 2004;421:162–168

Singh JA, Kwoh CK, Richardson D, Chen W, Ibrahim SA. Gender and surgical outcomes and mortality after primary total knee arthroplasty: A risk-adjusted analysis. Arthritis Care Res (Hoboken). 2013

Gioe TJ, Novak C, Sinner P, Ma W, Mehle S. Knee arthroplasty in the young patient: survival in a community registry. Clin Orthop Relat Res. 2007;464:83-87

Jain NB, Higgins LD, Ozumba D, Guller U, Cronin M, Pietrobon R, Katz JN. Trends in epidemiology of knee arthroplasty in the United States, 1990-2000. Arthritis Rheum. 2005;52:3928-3933

Losina E, Thornhill TS, Rome BN, Wright J, Katz JN. The dramatic increase in total knee replacement utilization rates in the United States cannot be fully explained by growth in population size and the obesity epidemic. J Bone Joint Surg Am. 2012;94:201-20

Downloads

Published

2015-10-31

How to Cite

Zandee van Rilland, E. D., Varcadipane, J. C., Geling, O., Murai Kuba, M., & Nakasone, C. K. (2015). A Minimum 2-Year Follow-up Using Modular Trabecular Metal Tibial Components in Total Knee Arthroplasty. Reconstructive Review, 5(3). https://doi.org/10.15438/rr.5.3.113

Issue

Section

Original Article