Patient Specific Component Alignment in Total Hip Arthroplasty
DOI:
https://doi.org/10.15438/rr.6.4.148Keywords:
Total Hip, Arthroplasty, Implant PositioningAbstract
Appropriate component alignment is critical for reducing instability, maximising bearing performance and restoring native anatomy after Total Hip Replacement (THR). Due to the large variation in patient kinematics between functional activities, current technologies lack definition of what constitutes correct target alignment. Analysis of a large series of symptomatic THR patients confirm that apparently well-orientated components on standard radiographs can still fail due to functional component malalignment. Evidently, previously defined “safe zones” are not appropriate for all patients as they don’t consider the dynamic behaviour of the hip joint.
The Optimized Positioning SystemTM (OPSTM) comprises preoperative planning based on a patient-specific dynamic analysis, and patient-specific instrumentation for delivery of the target component alignment. This paper presents the application of OPSTM in three case studies.
References
Annual Report 2015. Australian National Joint Replacement Registry.
Callanan, M.C., et al., The John Charnley Award: risk factors for cup malpositioning: quality improvement through a joint registry at a tertiary hospital. Clin Orthop Relat Res, 2011. 469(2): p. 319-29.
Grammatopoulos, G., et al., The effect of orientation of the acetabular component on outcome following total hip arthroplasty with small diameter hard-on-soft bearings. Bone Joint J, 2015. 97-B(2): p. 164-72.
Barrack, R.L., et al., Accuracy of acetabular component position in hip arthroplasty. J Bone Joint Surg Am, 2013. 95(19): p. 1760-8.
Abdel, M.P., et al., What Safe Zone? The Vast Majority of Dislocated THAs Are Within the Lewinnek Safe Zone for Acetabular Component Position. Clin Orthop Relat Res, 2016. 474(2): p. 386-91.
Nadzadi, M.E., et al., Kinematics, kinetics, and finite element analysis of commonplace maneuvers at risk for total hip dislocation. J Biomech, 2003. 36(4): p. 577-91.
Lazennec, J.Y., et al., Acetabular anteversion with CT in supine, simulated standing, and sitting positions in a THA patient population. Clin Orthop Relat Res, 2011. 469(4): p. 1103-9.
DiGioia, A.M., et al., Functional pelvic orientation measured from lateral standing and sitting radiographs. Clin Orthop Relat Res, 2006. 453: p. 272-6.
Philippot, R., et al., Pelvic balance in sagittal and Lewinnek reference planes in the standing, supine and sitting positions. Orthop Traumatol Surg Res, 2009. 95(1): p. 70-6.
Pierrepont, J., et al., Pelvic Tilt in the Standing, Supine and Seated Positions. Orthopaedic Proceedings, 2016. 98-B(SUPP 9): p. 30-30.
Pierrepont, J., et al., Functional orientation of the acetabular component in ceramic-on-ceramic total hip arthroplasty and its relevance to squeaking. Bone Joint J, 2016. 98-B(7).
Marel, E., et al., Patient-Specific Acetabular Cup Orientation in Functional Positions Using Musculoskeletal Modelling: A Pre-operative Planning Tool. Orthopaedic Proceedings, 2016. 98-B(SUPP 3): p. 19-19.
Udofia, I.J., A. Yew, and Z.M. Jin, Contact mechanics analysis of metal-on-metal hip resurfacing prostheses. Proc Inst Mech Eng H, 2004. 218(5): p. 293-305.
Matthies, A.K., et al., Predicting wear and blood metal ion levels in metal-on-metal hip resurfacing. J Orthop Res, 2014. 32(1): p. 167-74.
Murray, D.W., The definition and measurement of acetabular orientation. J Bone Joint Surg Br, 1993. 75(2): p. 228-32.
Kalteis, T., et al., Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation? J Bone Joint Surg Br, 2006. 88(2): p. 163-7.
Lass, R., et al., Total hip arthroplasty using imageless computer-assisted hip navigation: a prospective randomized study. J Arthroplasty, 2014. 29(4): p. 786-91.
Hohmann, E., A. Bryant, and K. Tetsworth, A comparison between imageless navigated and manual freehand technique acetabular cup placement in total hip arthroplasty. J Arthroplasty, 2011. 26(7): p. 1078-82.
Gurgel, H.M., et al., Acetabular component positioning in total hip arthroplasty with and without a computer-assisted system: a prospective, randomized and controlled study. J Arthroplasty, 2014. 29(1): p. 167-71.
Domb, B.G., et al., Comparison of robotic-assisted and conventional acetabular cup placement in THA: a matched-pair controlled study. Clin Orthop Relat Res, 2014. 472(1): p. 329-36.
Redmond, J.M., et al., Accuracy of Component Placement in Robotic-Assisted Total Hip Arthroplasty. Orthopedics, 2016: p. 1-7.
Lembeck, B., et al., Pelvic tilt makes acetabular cup navigation inaccurate. Acta Orthop, 2005. 76(4): p. 517-23.
Marel, E., et al., Investigation of Patient-Specific Acetabular Cup Malorientation in Functional Positions in the Failing Total Hip Replacement. Orthopaedic Proceedings, 2016. 98-B(SUPP 3): p. 20-20.
Spencer-Gardner, L., et al., Patient-specific instrumentation leads to accurate acetabular component placement in total hip arthroplasty. Bone Joint J, 2016. (In press).
Dimitriou, D., T.Y. Tsai, and Y.M. Kwon, The effect of femoral neck osteotomy on femoral component position of a primary cementless total hip arthroplasty. Int Orthop, 2015. 39(12): p. 2315-21.
Pierrepont, J., et al., Clinical Accuracy of a Patient-Specific Guide for Delivering a Planned Femoral Neck Osteotomy. Orthopaedic Proceedings, 2016. 98-B(SUPP 9): p. 131-131.
Published
How to Cite
Issue
Section
License
Copyright (c) 2016 James William Pierrepont, Catherine Zoe Stambouzou, Brad Peter Miles, Peter Bede O'Connor, Leonard Walter, Andrew Ellis, Rob Molnar, Jonathan Victor Baré, Michael Solomon, Stephen McMahon, Andrew Shimmin, Ed Marel

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Copyright and License Agreement:
Authors who publish with the Reconstructive Review agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work. Reconstructive Review follows the Creative Commons Attribution-NonCommercial CC BY-NC. This license allows anyone to download works, build upon the material, and share them with others for non-commercial purposes as long as they credit the senior author, Reconstructive Review, and the Joint Implant Surgery & Research Foundation (JISRF). An example credit would be: "Courtesy of (senior author's name), Reconstructive Review, JISRF, Chagrin Falls, Ohio". While works can be downloaded and shared they cannot be used commercially.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work.