Conversion Knee Arthroplasty Using a Rotating Hinge as a Salvage Prosthesis Following Periprosthetic Joint Infection and Ligamentous Insufficiency: A Case Report

Authors

  • Jon E. Minter Arthritis & Total Joint Specialists

DOI:

https://doi.org/10.15438/rr.8.1.208

Keywords:

Complex Revision TKA, Rotating Hinge TKA, Non-Articulating Fusion, Salvage TKA

Abstract

Background

In the event of a complex revision TKA in which there is extensor mechanism involvement and ligamentous instability or insufficiency, non-linked levels of constraint may not be adequate for achieving restoration of patient function. Total knee arthroplasty devices that incorporate a linked level of constraint are successful alternatives to unlinked devices (PS and PS-Constrained) in this clinical context.

Case Presentation

We present the case of a 62 year-old male patient that required a non-articulating knee fusion and multiple total knee arthroplasty revisions in conjunction with a ruptured and repaired extensor mechanism, ligamentous instability, bone loss and periprosthetic joint infection.  (Revision knee prosthesis that includes a increasing degree of nodularity and physical constraint).  The subsequent risk factors associated with the loss of bone and ligamentous insufficiency required performing conversion arthroplasty with a knee prosthesis that includes an increasing degree of modularity and physical constraint not commonly used in revision total knee arthroplasty.

Discussion

The authors report on a patient who underwent multiple operative procedures, we outline the step wise decision making progression that lead to the successful eradication of the PJI and reimplant device strategy based on the confounding factors presented.  We assess the use of revision TKA systems that offer extreme degrees of constraint which should be considered in complex revision knee revision procedures.

References

Ong, K.L., et al., Risk of subsequent revision after primary and revision total joint arthroplasty. Clin Orthop Relat Res, 2010. 468(11): p. 3070-6.

Lai, K., et al., Presence of medical comorbidities in patients with infected primary hip or knee arthroplasties. J Arthroplasty, 2007. 22(5): p. 651-6.

Bozic, K.J., et al., Patient-related risk factors for periprosthetic joint infection and postoperative mortality following total hip arthroplasty in Medicare patients. J Bone Joint Surg Am, 2012. 94(9): p. 794-800.

Victor, J., et al., Total knee arthroplasty at 15-17 years: does implant design affect outcome? Int Orthop, 2014. 38(2): p. 235-41.

Uvehammer, J., Knee joint kinematics, fixation and function related to joint area design in total knee arthroplasty. Acta Orthop Scand Suppl, 2001. 72(299): p. 1-52.

Firestone, T.P. and R.W. Eberle, Surgical management of symptomatic instability following failed primary total knee replacement. J Bone Joint Surg Am, 2006. 88 Suppl 4: p. 80-4.

Barrack, R.L., et al., The use of a modular rotating hinge component in salvage revision total knee arthroplasty. J Arthroplasty, 2000. 15(7): p. 858-66.

Lombardi, A.V., Jr., et al., Rotating hinge prosthesis in revision total knee arthroplasty: indications and results. Surg Technol Int, 1997. 6: p. 379-82.

Parvizi, J., et al., The 2018 Definition of Periprosthetic Hip and Knee Infection: An Evidence-Based and Validated Criteria. J Arthroplasty, 2018. 33(5): p. 1309-1314 e2.

Bozic, K.J., et al., The epidemiology of revision total knee arthroplasty in the United States. Clin Orthop Relat Res, 2010. 468(1): p. 45-51.

Waterman JA, M.J. Minter, Ghattas PJ, Green BM, The Impact of use of Double Set-up on Infection Rates in Revision Total Knee Replacement and Limb Salvage Procedures. Reconstructive Review, 2015. 5(1).

Paulos, L.E., et al., The biomechanics of lateral knee bracing. Part I: Response of the valgus restraints to loading. Am J Sports Med, 1987. 15(5): p. 419-29.

France, E.P., et al., The biomechanics of lateral knee bracing. Part II: Impact response of the braced knee. Am J Sports Med, 1987. 15(5): p. 430-8.

Marson, B.A., et al., Alpha-defensin and the Synovasure lateral flow device for the diagnosis of prosthetic joint infection. Bone Joint J, 2018. 100-B(6): p. 703-711.

de Saint Vincent, B., et al., Diagnostic accuracy of the alpha defensin lateral flow device (Synovasure) for periprosthetic infections in microbiologically complex situations: A study of 42 cases in a French referral centre. Orthop Traumatol Surg Res, 2018. 104(4): p. 427-431.

Guild, G.N., 3rd, B. Wu, and G.R. Scuderi, Articulating vs. Static antibiotic impregnated spacers in revision total knee arthroplasty for sepsis. A systematic review. J Arthroplasty, 2014. 29(3): p. 558-63.

Anagnostakos, K. and C. Meyer, Antibiotic Elution from Hip and Knee Acrylic Bone Cement Spacers: A Systematic Review. Biomed Res Int, 2017. 2017: p. 4657874.

Cho, S.H., et al., Two-stage conversion of fused knee to total knee arthroplasty. J Arthroplasty, 2008. 23(3): p. 476-9.

Henkel, T.R., et al., Total knee arthroplasty after formal knee fusion using unconstrained and semiconstrained components: a report of 7 cases. J Arthroplasty, 2001. 16(6): p. 768-76.

Wiedel, J.D., Salvage of infected total knee fusion: the last option. Clin Orthop Relat Res, 2002(404): p. 139-42.

Parvizi J, G.T., Proceedings of the International Consensus Meeting on Periprosthetic Joint Infection. . J Arthroplasty, 2014. 29 Suppl 1(2): p. 1-130.

Sanguineti, F., et al., Total knee arthroplasty with rotating-hinge Endo-Model prosthesis: clinical results in complex primary and revision surgery. Arch Orthop Trauma Surg, 2014. 134(11): p. 1601-7.

Bistolfi, A., et al., Results with 98 Endo-Modell rotating hinge prostheses for primary knee arthroplasty. Orthopedics, 2013. 36(6): p. e746-52.

Downloads

Published

2018-10-16

How to Cite

Minter, J. E. (2018). Conversion Knee Arthroplasty Using a Rotating Hinge as a Salvage Prosthesis Following Periprosthetic Joint Infection and Ligamentous Insufficiency: A Case Report. Reconstructive Review, 8(1). https://doi.org/10.15438/rr.8.1.208

Issue

Section

Case Report