Successful Closed Reduction of a Dislocated Constrained Total Hip Arthroplasty

Authors

  • Motoki Sonohata
  • Warit Waewsawangwong
  • Stuart Goodman

DOI:

https://doi.org/10.15438/rr.v3i4.48

Abstract

This case report and literature review examines whether closed reduction is a viable option to manage hip dislocation when the patient has a constrained liner. 

 

 

Introduction

 

Dislocation after total hip arthroplasty (THA) ranges from less than 1% to 6% of primary cases [1] and from 15% to 30% of revision cases [2]. Unfortunately, the success rate of non-operative treatment of dislocation after THA can be unreliable, and a third of such patients have recurrences [1].

Surgical procedures used to treat instability and dislocation include:

•Tightening the abductor musculature

•Removing sources of impingement

•Repositioning malaligned components

•Using acetabular liners with elevated rims

Such treatments fail in 30% to 50% of patients, however [3].

The use of constrained liners, which relies on a locking mechanism to capture the femoral head, has been developed to help manage this problem [4]. Despite such efforts, patients continue to be at high risk for instability, and 3% to 18% experience recurrent dislocation even after constrained components have been implanted [5,6]. Generally, open surgical reduction is thought to be the only available treatment for such cases. However, this compromises the integrity of the joint and exposes the patient to the additional risk of surgery [7]. Several authors have reported closed reduction for dislocation of a constrained liner [7-13].

Constrained acetabular liners are currently available in various designs, with differences in the locking mechanisms. To our knowledge, ours is the first reported case of a successful closed reduction of a dislocated constrained THA using a Trilogy Acetabular System Constrained liner (Zimmer, Inc, Warsaw, Indiana, USA).

The study protocol adhered to the ethics guidelines of the 1975 Declaration of Helsinki, and the study was approved by the Institutional Review Board of Stanford University.

References

Soong M, Rubash HE, Macaulay W. Dislocation after total hip arthroplasty. J Am Acad Orthop Surg 2004; 12(5): 314-21.

Su EP, Pellicci PM. The role of constrained liners in total hip arthroplasty. Clin Orthop 2004; 420: 122-9.

Morrey BF. Difficult complications after hip joint replacement. Dislocation. Clin Orthop 1997; 344: 179-87.

Shrader MW, Parvizi J, Lewallen DG. The use of a constrainedacetabular component to treat instability after total hip arthroplasty. J Bone Joint Surg Am 2003; 85(11): 2179-83.

Berend KR, Lombardi AV Jr, Mallory TH, Adams JB, Russell JH,Groseth KL. The long-term outcome of 755 consecutive constrained acetabular components in total hip arthroplasty examining the successes and failures. J Arthroplasty 2005; 20(7 Suppl. 3): 93-102.

Khan RJ, Fick D, Alakeson R, et al. A constrained acetabular component for recurrent dislocation. J Bone Joint Surg Br 2006; 88(7): 870-6.

McPherson EJ, Costigan WM, Gerhardt MB, Norris LR. Closed reduction of dislocated total hip with S-ROM constrained acetabular component. J Arthroplasty 1999; 14(7): 882-5.

Miller CW, Zura RD. Closed reduction of a dislocation of aconstrained acetabular component. J Arthroplasty 2001; 16(4): 504-5.

Harman MK, Hodge WA, Banks SA. Closed reduction of constrained total hip arthroplasty. Clin Orthop 2003; 414: 121-8.

Birdwell S, Wilke E. Closed reduction of constrained total hip arthroplasty in the ED. J Emerg Med 2011; 40(2): 162-6.

Robertson WJ, Mattern CJ, Hur J, Su EP, Pellicci PM. Failure mechanisms and closed reduction of a constrained tripolar acetabular liner. J Arthroplast 2009; 24(2): 322.e5-11.

Gaines RJ, Hardenbrook M. Closed reduction of a dislocated total hip arthroplasty with a constrained acetabular component. Am J Orthop (Belle Mead NJ) 2009; 38(10): 523-5.

Flint JH, Phisitkul P, Callaghan JJ. Closed reduction of a dislocated constrained total hip arthroplasty using a novel technique with a peg board. Orthopedics 2010; 10: 201-3.

Downloads

Published

2013-12-30

How to Cite

Sonohata, M., Waewsawangwong, W., & Goodman, S. (2013). Successful Closed Reduction of a Dislocated Constrained Total Hip Arthroplasty. Reconstructive Review, 3(3). https://doi.org/10.15438/rr.v3i4.48

Issue

Section

Original Article