Successful Closed Reduction of a Dislocated Constrained Total Hip Arthroplasty
DOI:
https://doi.org/10.15438/rr.v3i4.48Abstract
This case report and literature review examines whether closed reduction is a viable option to manage hip dislocation when the patient has a constrained liner.
Introduction
Dislocation after total hip arthroplasty (THA) ranges from less than 1% to 6% of primary cases [1] and from 15% to 30% of revision cases [2]. Unfortunately, the success rate of non-operative treatment of dislocation after THA can be unreliable, and a third of such patients have recurrences [1].
Surgical procedures used to treat instability and dislocation include:
•Tightening the abductor musculature
•Removing sources of impingement
•Repositioning malaligned components
•Using acetabular liners with elevated rims
Such treatments fail in 30% to 50% of patients, however [3].
The use of constrained liners, which relies on a locking mechanism to capture the femoral head, has been developed to help manage this problem [4]. Despite such efforts, patients continue to be at high risk for instability, and 3% to 18% experience recurrent dislocation even after constrained components have been implanted [5,6]. Generally, open surgical reduction is thought to be the only available treatment for such cases. However, this compromises the integrity of the joint and exposes the patient to the additional risk of surgery [7]. Several authors have reported closed reduction for dislocation of a constrained liner [7-13].
Constrained acetabular liners are currently available in various designs, with differences in the locking mechanisms. To our knowledge, ours is the first reported case of a successful closed reduction of a dislocated constrained THA using a Trilogy Acetabular System Constrained liner (Zimmer, Inc, Warsaw, Indiana, USA).
The study protocol adhered to the ethics guidelines of the 1975 Declaration of Helsinki, and the study was approved by the Institutional Review Board of Stanford University.
References
Soong M, Rubash HE, Macaulay W. Dislocation after total hip arthroplasty. J Am Acad Orthop Surg 2004; 12(5): 314-21.
Su EP, Pellicci PM. The role of constrained liners in total hip arthroplasty. Clin Orthop 2004; 420: 122-9.
Morrey BF. Difficult complications after hip joint replacement. Dislocation. Clin Orthop 1997; 344: 179-87.
Shrader MW, Parvizi J, Lewallen DG. The use of a constrainedacetabular component to treat instability after total hip arthroplasty. J Bone Joint Surg Am 2003; 85(11): 2179-83.
Berend KR, Lombardi AV Jr, Mallory TH, Adams JB, Russell JH,Groseth KL. The long-term outcome of 755 consecutive constrained acetabular components in total hip arthroplasty examining the successes and failures. J Arthroplasty 2005; 20(7 Suppl. 3): 93-102.
Khan RJ, Fick D, Alakeson R, et al. A constrained acetabular component for recurrent dislocation. J Bone Joint Surg Br 2006; 88(7): 870-6.
McPherson EJ, Costigan WM, Gerhardt MB, Norris LR. Closed reduction of dislocated total hip with S-ROM constrained acetabular component. J Arthroplasty 1999; 14(7): 882-5.
Miller CW, Zura RD. Closed reduction of a dislocation of aconstrained acetabular component. J Arthroplasty 2001; 16(4): 504-5.
Harman MK, Hodge WA, Banks SA. Closed reduction of constrained total hip arthroplasty. Clin Orthop 2003; 414: 121-8.
Birdwell S, Wilke E. Closed reduction of constrained total hip arthroplasty in the ED. J Emerg Med 2011; 40(2): 162-6.
Robertson WJ, Mattern CJ, Hur J, Su EP, Pellicci PM. Failure mechanisms and closed reduction of a constrained tripolar acetabular liner. J Arthroplast 2009; 24(2): 322.e5-11.
Gaines RJ, Hardenbrook M. Closed reduction of a dislocated total hip arthroplasty with a constrained acetabular component. Am J Orthop (Belle Mead NJ) 2009; 38(10): 523-5.
Flint JH, Phisitkul P, Callaghan JJ. Closed reduction of a dislocated constrained total hip arthroplasty using a novel technique with a peg board. Orthopedics 2010; 10: 201-3.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2014 Motoki Sonohata, Warit Waewsawangwong, Stuart Goodman

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Copyright and License Agreement:
Authors who publish with the Reconstructive Review agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work. Reconstructive Review follows the Creative Commons Attribution-NonCommercial CC BY-NC. This license allows anyone to download works, build upon the material, and share them with others for non-commercial purposes as long as they credit the senior author, Reconstructive Review, and the Joint Implant Surgery & Research Foundation (JISRF). An example credit would be: "Courtesy of (senior author's name), Reconstructive Review, JISRF, Chagrin Falls, Ohio". While works can be downloaded and shared they cannot be used commercially.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work.