Osseointegration Implant Post Coupling With External Prosthetic Limb – Continuation of Previous Case Reports “Stage III”

Authors

  • Ronald Hillock, MD
  • Danny Tatum, BCP
  • Edward Dolegowski, PT

DOI:

https://doi.org/10.15438/rr.v4i2.68

Abstract

An ongoing update of the progress case report for the first patient treated with the Longitude™ osseointegration prosthesis implanted in an amputated residual femur is presented. The patient was given an intensive physical therapy program of strengthening and conditioning in anticipation of coupling to the external prosthesis. A custom prosthesis was fabricated based on the Plie’ 2.0 microprocessor knee system. The patient was then successfully trained on use and care of the prosthesis for ambulation without any complications.

Keywords: Amputation, Osseointegration

Acknowledgement: Design concept by Concept Design & Development, LLC (CDD,LLC); Development and Manufacturing by Signature Orthopaedics, LTD; Centennial Hills Hospital Medical Center, Las Vegas, NV; and Institutional Review Board (IRB) by Joint Implant Surgery & Research Foundation.

References

http://www.signatureortho.com.au/ Accessed May 24, 2014.

Hillock RW, Keggi J, Kennon R, McPherson E, Clyburn T, Brazil D, McTighe T. A global collaboration- osseointegration implant (OI) for transfemoral amputation.

Recon Review. 2013; 3(2): 50-4.

Hillock RW, Keggi J, Kennon R, McPherson E, Clyburn T, Brazil D, McTighe T. Stage II osteonintegration implant (OI) skin coupling procedure. Recon Review. 2013; 3(4): 62-6.

http://silverlon.com/advanced-wound-care-dressings/ Accessed May 24, 2014.

http://www.thera-band.com/ Accessed May 24, 2014.

http://www.freedom-innovations.com/knees/ Accessed May 24, 2014.

Gailey RS, et al. The amputee mobility predictor: an instrument to assess determinants of the lower limb amputee’s ability to ambulate. Arch Phys Med Rehab.

; 83: 613-26.

http://www.amputee-life.org/2012/10/28/amputee-k-levels/ Accessed May 24, 2014.

http://www.ottobockus.com/accessories/accessories-prosthetics/battery-chargerc-leg.html. Accessed May 24, 2014.

http://www.ottobock.com/cps/rde/xchg/ob_com_en/hs.xsl/5489.html. Accessed May 24, 2014.

http://www.endolite.com/products/multiflex-standard/ Accessed May 24, 2014.

Aschoff HH, Clausen A, Tsoumpris K, Hoffmeister T. Implantation of the endoexo femur prosthesis to improve mobility of amputees. Oper Ortho Traumatol. 2011; 23(5): 462-72.

Haggstrom E, Hagberg K, Rydevik B, Branemark R. Vibrotactile evaluation: osseointegrated versus socket-suspended transfemoral prosthesis. J Rehab Res Dev. 2013; 50(10): 1423-34.